APPLICATION

The SPD normally is installed in the building power distribution box, computer center,telecom room, elevator control room, wiring tv room, building control room, security monitor center, fire control center ,industry control room, frequency converter equipment control room, hospital surgery room, monitoring room and the distribution box in whichelectronic mechanical equipment.

 

COMPONENTS INSTRODUCTION

 

  • Invalid tripping device

      There is invalid tripping device on the protector modular, when the protector is invalid cause of over thermal, breakdown, the invalid tripping device can separate from the power grid automatically and the indication signal is sent out. When the protector is normal, the green is displayed ,when invalid tripping,

red is displayed.

  • Alarming apparatus

     The alarming apparatus is power supplied by 220VAC,the indication lamp is green when the protector work normally, normal open contact is closed and the normal closed contact is open. Audio light alarming function: when the protection modular is invalid , the alarm will be beeping ,the normal green lamp will be changed into red lamp at the same time. When the maintainer press the stop button, the buzz will stop ,but the red lamp still is on, if the fault is not solved within 24 hours, the alarming apparatus will send out beep once again.

  • Remote signal contact

      The protector can be with remote signal contact, the contact is normal open, if one or moremodular of protector is invalid, the contact will be closed and send out fault signal. The rated parameter of remote signal contact isA C36V,1A.

The SPD normally is installed in the building power distribution box, computer center,telecom room, elevator control room, wiring tv room, building control room, security monitor center, fire control center ,industry control room, frequency converter equipment control room, hospital surgery room, monitoring room and the distribution box in whichelectronic mechanical equipment.

 

COMPONENTS INSTRODUCTION

 

  • Invalid tripping device

      There is invalid tripping device on the protector modular, when the protector is invalid cause of over thermal, breakdown, the invalid tripping device can separate from the power grid automatically and the indication signal is sent out. When the protector is normal, the green is displayed ,when invalid tripping,

red is displayed.

  • Alarming apparatus

     The alarming apparatus is power supplied by 220VAC,the indication lamp is green when the protector work normally, normal open contact is closed and the normal closed contact is open. Audio light alarming function: when the protection modular is invalid , the alarm will be beeping ,the normal green lamp will be changed into red lamp at the same time. When the maintainer press the stop button, the buzz will stop ,but the red lamp still is on, if the fault is not solved within 24 hours, the alarming apparatus will send out beep once again.

  • Remote signal contact

      The protector can be with remote signal contact, the contact is normal open, if one or moremodular of protector is invalid, the contact will be closed and send out fault signal. The rated parameter of remote signal contact isA C36V,1A.

em DC SURGE PROTECTIVE DEVICE
Code FSP-D40
Pole 2P 3P
Voltage 500VDC,600VDC 800VDC,900VDC,1000VDC
In(8/20)us(KA) 20KA
Imax(8/20)us(KA) 40KA
Standard IEC/EN61643
Type II
Characteristic Curve B,C,D
Working Temperature “-5°”to +40°
Protection Degree IP20
Electrical life  More than 8000times
Mechanical life More than 2000times
Dimension(W)X(H)X(D) 36x90x68 54x90x68
Installation 35MM DIN RAIL
Accessory Remote signal
Installation Altitude ≤2000M

 

Parameter item Model

Model

GNS1-D/

-140-5(10)

GNS1-D/

-275-5(10)

GNS1-D/

-320-5(10)

GNS1-D/

-385-5(10)

GNS1-D/

-420-5(10)

Max continuous

operation voltage UC~(V)

140

275

320

385

420

Voltage protection

level UP(KV)

<=1.0

<=1.0

<=1.5

<=2.0

<=2.0

Nominal discharging

current In(8/20u S) KA

5 10

Max discharging current

Imax(8/20u.S)KA

10 20

Response time ns

<25

Width mm

18

color

yellow

Protection degree

IP20

Shell material

Strong flame-retardant PBT

Fuse or circuit breaker(A)

10-16

Connection

specification

Phase/zero line

2.5-35mm2

Earth line

4.0-35mm2

Signal line

1.5mm2

 

SPD sparespd specificationspd wirespd sizespd din roilspdspd Materials

Anterior: 
Siguiente: 

Categoría del producto

Singi Electrical, fundada en 1995, es una empresa de alta tecnología que se especializa en la fabricación y la comercialización de interruptores de circuitos de bajo voltaje ...

Información

Nuestros productos

Contáctanos

Teléfono:0577 62053322
Whatsapp:18868286161
Correo electrónico:chaoransang@singi.com
 
Derechos de autor © 2023 - 2024 todos los derechos reservados.